Advantages of the inductive detection
1.No physical contact with the object to be detected , thus avoiding wear andenabling fragile or freshly painted objects to be detected
2.High operating rates
3.Fast responsee Excellent resistance to industrial environments
INDUCTIVE PROXIMITY SWITCH | ||||
Structural category | Plane installation type | |||
Outward appearance code | LM36 | |||
Appearance |
| |||
Dimension | | |||
Flush | Detection distance | |||
NPN | NO | |||
DC | NC | |||
6 | NO+NC | |||
~ | PNP | NO | ||
36 | NC | |||
V | NO+NC | |||
two wire system | NO | |||
NC | ||||
AC | SRC Control label silicon | NO | ||
90 | NC | |||
~250 | NO+NC | |||
V | Relay output | |||
Non-flush | Detection distance | 10mm | ||
NPN | NO | 3010NA | ||
NC | 3010NB | |||
DC | NO+NC | 3010NC | ||
6 | PNP | NO | 3010PA | |
~ | NC | 3010PB | ||
36 | NO+NC | 3010PC | ||
V | two wire system | NO | 3010LA | |
NC | 3010LB | |||
AC | SRC Control label silicon | NO | 2010A | |
90 | NC | 2010B | ||
~250 | NO+NC | |||
V | Relay output | |||
Control output | DC | 300mA | ||
SCR/Relay | 500mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 45×45×1(A3 iron) | |||
Repeated precision | 0.02 | |||
DC/AC Response frequency | 200Hz/20Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | 50MΩ | |||
Shell material | ABS Resin | |||
Protection grade | IEC standard IP67 |
Advantages of the inductive detection
1.No physical contact with the object to be detected , thus avoiding wear andenabling fragile or freshly painted objects to be detected
2.High operating rates
3.Fast responsee Excellent resistance to industrial environments
INDUCTIVE PROXIMITY SWITCH | ||||
Structural category | Plane installation type | |||
Outward appearance code | LM36 | |||
Appearance |
| |||
Dimension | | |||
Flush | Detection distance | |||
NPN | NO | |||
DC | NC | |||
6 | NO+NC | |||
~ | PNP | NO | ||
36 | NC | |||
V | NO+NC | |||
two wire system | NO | |||
NC | ||||
AC | SRC Control label silicon | NO | ||
90 | NC | |||
~250 | NO+NC | |||
V | Relay output | |||
Non-flush | Detection distance | 10mm | ||
NPN | NO | 3010NA | ||
NC | 3010NB | |||
DC | NO+NC | 3010NC | ||
6 | PNP | NO | 3010PA | |
~ | NC | 3010PB | ||
36 | NO+NC | 3010PC | ||
V | two wire system | NO | 3010LA | |
NC | 3010LB | |||
AC | SRC Control label silicon | NO | 2010A | |
90 | NC | 2010B | ||
~250 | NO+NC | |||
V | Relay output | |||
Control output | DC | 300mA | ||
SCR/Relay | 500mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 45×45×1(A3 iron) | |||
Repeated precision | 0.02 | |||
DC/AC Response frequency | 200Hz/20Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | 50MΩ | |||
Shell material | ABS Resin | |||
Protection grade | IEC standard IP67 |