Availability: | |
---|---|
Quantity: | |
Inductive proximity sensors enable the detection, without contact, of metalobjects at distances of up to 60 mm.Their range of applications is very extensive and includes: the monitoring of machine parts(cams, mechanical stops, etc. ) monitoring the flow of metal parts, counting, etc.
INDUCTIVE PROXIMITY SWITCH | ||||
Outward appearance code | LM22-££T | |||
Appearance |
| |||
Dimension |
| |||
Flush | Detection distance | 7mm | ||
NPN | NO | 3007NAT | ||
DC | NC | 3007NBT | ||
6 | NO+NC | 3007NCT | ||
~ | PNP | NO | 3007PAT | |
36 | NC | 3007PBT | ||
V | NO+NC | 3007PCT | ||
two wire system | NO | 3007LAT | ||
NC | 3007LBT | |||
AC | SRC Control label silicon | NO | 2007AT | |
90 | NC | 2007BT | ||
~250 | NO+NC | 2007CT | ||
V | Relay output | |||
Non-flush | Detection distance | 10mm | ||
NPN | NO | 3010NAT | ||
NC | 3010NBT | |||
DC | NO+NC | 3010NCT | ||
6 | PNP | NO | 3010PAT | |
~ | NC | 3010PBT | ||
36 | NO+NC | 3010PCT | ||
V | two wire system | NO | 3010LAT | |
NC | 3010LBT | |||
AC | SRC Control label silicon | NO | 2010AT | |
90 | NC | 2010BT | ||
~250 | NO+NC | 2010CT | ||
V | Relay output | |||
Control output | DC | 200mA | ||
SCR/Relay | 300mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 22×22×1(A3 iron) | |||
Repeated precision | 0.05 | |||
DC/AC Response frequency | 200Hz/25Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | 50MΩ | |||
Shell material | Metal | |||
Protection grade | IEC standard IP67 |
Inductive proximity sensors enable the detection, without contact, of metalobjects at distances of up to 60 mm.Their range of applications is very extensive and includes: the monitoring of machine parts(cams, mechanical stops, etc. ) monitoring the flow of metal parts, counting, etc.
INDUCTIVE PROXIMITY SWITCH | ||||
Outward appearance code | LM22-££T | |||
Appearance |
| |||
Dimension |
| |||
Flush | Detection distance | 7mm | ||
NPN | NO | 3007NAT | ||
DC | NC | 3007NBT | ||
6 | NO+NC | 3007NCT | ||
~ | PNP | NO | 3007PAT | |
36 | NC | 3007PBT | ||
V | NO+NC | 3007PCT | ||
two wire system | NO | 3007LAT | ||
NC | 3007LBT | |||
AC | SRC Control label silicon | NO | 2007AT | |
90 | NC | 2007BT | ||
~250 | NO+NC | 2007CT | ||
V | Relay output | |||
Non-flush | Detection distance | 10mm | ||
NPN | NO | 3010NAT | ||
NC | 3010NBT | |||
DC | NO+NC | 3010NCT | ||
6 | PNP | NO | 3010PAT | |
~ | NC | 3010PBT | ||
36 | NO+NC | 3010PCT | ||
V | two wire system | NO | 3010LAT | |
NC | 3010LBT | |||
AC | SRC Control label silicon | NO | 2010AT | |
90 | NC | 2010BT | ||
~250 | NO+NC | 2010CT | ||
V | Relay output | |||
Control output | DC | 200mA | ||
SCR/Relay | 300mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 22×22×1(A3 iron) | |||
Repeated precision | 0.05 | |||
DC/AC Response frequency | 200Hz/25Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | 50MΩ | |||
Shell material | Metal | |||
Protection grade | IEC standard IP67 |
content is empty!