Inductive proximity sensors enable the detection, without contact, of metalobjects at distances of up to 60 mm.Their range of applications is very extensive and includes: the monitoring of machine parts(cams, mechanical stops, etc. ) monitoring the flow of metal parts, counting, etc.
INDUCTIVE PROXIMITY SWITCH | ||||
Outward appearance code | LM14 | |||
Appearance |
| |||
Dimension | | |||
Flush | Detection distance | 3mm | ||
NPN | NO | 3003NAT | ||
DC | NC | 3003NBT | ||
6 | NO+NC | 3003NCT | ||
~ | PNP | NO | 3003PAT | |
36 | NC | 3003PBT | ||
V | NO+NC | 3003PCT | ||
two wire system | NO | 3003LAT | ||
NC | 3003LBT | |||
AC | SRC Control label silicon | NO | 2003AT | |
90 | NC | 2003BT | ||
~250 | NO+NC | |||
V | Relay output | |||
Non-flush | Detection distance | 5mm | ||
NPN | NO | 3005NAT | ||
NC | 3005NBT | |||
DC | NO+NC | 3005NCT | ||
6 | PNP | NO | 3005PAT | |
~ | NC | 3005PBT | ||
36 | NO+NC | 3005PCT | ||
V | two wire system | NO | 3005LAT | |
NC | 3005LB | |||
AC | SRC Control label silicon | NO | 2005AT | |
90 | NC | 2005BT | ||
~250 | NO+NC | |||
V | Relay output | |||
Control output | DC | 200mA | ||
SCR/Relay | 300mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 15×15×1(A3 iron) | |||
Repeated precision | 0.02 | |||
DC/AC Response frequency | 300Hz/25Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | ≥50MΩ | |||
Shell material | Metal | |||
Protection grade | IEC standard IP67 |
Inductive proximity sensors enable the detection, without contact, of metalobjects at distances of up to 60 mm.Their range of applications is very extensive and includes: the monitoring of machine parts(cams, mechanical stops, etc. ) monitoring the flow of metal parts, counting, etc.
INDUCTIVE PROXIMITY SWITCH | ||||
Outward appearance code | LM14 | |||
Appearance |
| |||
Dimension | | |||
Flush | Detection distance | 3mm | ||
NPN | NO | 3003NAT | ||
DC | NC | 3003NBT | ||
6 | NO+NC | 3003NCT | ||
~ | PNP | NO | 3003PAT | |
36 | NC | 3003PBT | ||
V | NO+NC | 3003PCT | ||
two wire system | NO | 3003LAT | ||
NC | 3003LBT | |||
AC | SRC Control label silicon | NO | 2003AT | |
90 | NC | 2003BT | ||
~250 | NO+NC | |||
V | Relay output | |||
Non-flush | Detection distance | 5mm | ||
NPN | NO | 3005NAT | ||
NC | 3005NBT | |||
DC | NO+NC | 3005NCT | ||
6 | PNP | NO | 3005PAT | |
~ | NC | 3005PBT | ||
36 | NO+NC | 3005PCT | ||
V | two wire system | NO | 3005LAT | |
NC | 3005LB | |||
AC | SRC Control label silicon | NO | 2005AT | |
90 | NC | 2005BT | ||
~250 | NO+NC | |||
V | Relay output | |||
Control output | DC | 200mA | ||
SCR/Relay | 300mA | |||
Output voltage dropDC/AC | DC<3V AC<10V | |||
Consumption current | DC<15mA AC<10mA | |||
Standard detected object | 15×15×1(A3 iron) | |||
Repeated precision | 0.02 | |||
DC/AC Response frequency | 300Hz/25Hz | |||
Working environment temperature | –25℃~75℃ | |||
Insulation resistance | ≥50MΩ | |||
Shell material | Metal | |||
Protection grade | IEC standard IP67 |